Metrotech logo
home   contact us   terms of use

FELL Electro-Scan
One-step Sewer Leak Detection & Location
ASCE Published Paper
Presented at ASCE Pipelines Conference Aug 2006

Field Application Of
Sewer Electro-Scan In
Large Pipe Condition Assessment

defect analysis histogram
Terry Moy, P.E.,ASCE(1), Glenn Coleman(2),
Charles Wilmut, P.E.(3)

(1) Project Director, Woolpert Inc., Atlanta, Georgia,
E-mail: terry.moy@woolpert.com, Tel (770) 993-5323.

(2) Public Utilities Assistant Director, Athens Clarke County, Georgia, 30603,
E-mail: glenncoleman@co.clarke.ga.us, Tel (706) 613-3470.

(3) Project Engineer, GSWW Inc., Dallas, Texas,
E-mail: cwilmut@gsw-inc.com, Tel (972) 620-1255
.


Paper available at: www.asce.org


Electro-Scan pipe defect analysis at a glance

Abstract
The use of condition assessment tools to help prioritize pipeline rehabilitation needs has continued to grow.  New tools and techniques that provide uniform, consistent results are needed to address the overwhelming backlog of pipelines that are nearing their useful service life.  Sewer electro-scan is one technology that provides some promise in meeting these needs.  This paper presents insights into the use of sewer electro-scan for large, gravity sewer applications.


Metrotech Corporation, 3251 Olcott St, Santa Clara  CA 95054. Ph: (408) 734-1400