Metrotech logo
home   contact us     terms of use

FELL Electro-Scan
One-step Sewer Leak Detection & Location
Comparison of
Sewer Evaluation Tools

Most cost effective pipe defect location test
detects all types of potential leakage faults
 - joints, service connections and cracks
whether actively flowing or not at the time of the test


Best Property

 

 

 

Property

Flow Monitoring

TV Inspection

Pressure Testing

Smoke Testing

Electro-Scanner

Test Rate(ft/day)

Months to Years

2,000 to 3,000

1,000 to 2,000

5,000 to 10,000

3,000 to 4,000

Interpretation Rate (ft/day)

Highly variable

4,000 to 6,000

10,000 to 20,000

10,000 to 20,000

16,000 to 20,000

Cost per foot*1

$0.15 to $0.30

$3.00 to $5.00

$4.00 to $5.00

$0.25 to $0.35

$1.00 to $2.00

Capital Cost

$40,000

$100,000+

Dedicated vehicle

$10,000 +

TV for Joint testing

$2,000

$25,000 to $40,000

 

Pipe Type

All

All -low flow

6 to 30 inch

6 to 30 inch

3 to 60 inch including laterals

Non-conducting*2

Conditions Required for Field Test Scheduling

Requires measurement of dry weather and storm events

Leaks must be active. (pipe below ground water level or during storm event)

Pipe cannot be surcharged

Pipe above ground water level. Months of dry weather prior to testing.

No wind.

None

Pipe Preparation

Hydraulic analysis and installation of monitors

Clean, Empty

No flow for 30 minutes. May require bypass pumping

No Roots or Grease.

No flow for 60 minutes. May require bypass pumping

Isolate pipe section Resident and emergency services notification

Partial Surcharge for

10 minutes

Portability*3

High

Low

Low

High

High

Output Data*4

Quantitative

Qualitative

Quantitative

Qualitative

Quantitative

Defect/Leak

Detection

All active leaks

Cannot detect pipe defects that are potential leaks.

Leaks flowing at time of test. Structural potential leak defects.*5

Cannot detect potential leak joint defects.

All pipe potential leak defects*5 except lateral connection from main.  Characterization of defects depends on test setup.

Some defects

All potential pipe leak defects.*5 Characterization of defects as structural, joint or lateral connection.

Defect/Leak size measurement.

Infiltration measurement for weather events captured

Descriptive estimate of active leaks

Pass/Fail

Descriptive estimate of defects

Amplitude of current trace related to size of defect

Location Accuracy

Within 1,000 to 15,000 ft

Within inches

No TV: within 300 feet

With TV: within inches

Highly variable

Within inches

Data reliability, consistency and repeatability

Moderate:

Dependant on time period and weather events captured

Moderate:

Dependant on experience of operator and interpreter.

Joint leaks must be active.

Moderate:

Depends on placement of plugs and test setup.

 

Low:

Highly dependant on surface and soil type/condition

High:

Independent of soil type and ground water level

QA Testing*6

High

Moderate

Moderate

Low

High

Field Crew Training

Weeks

Specialist

Months

Specialist

Weeks

Specialist

Days

Maintenance Crew

Days

Maintenance Crew

Interpretation Training

Specialist Professional

Specialist Technician

Technician

Technician

Technician

 

Notes:

1.        Cost per foot is based on typical contractor rates and includes pipe preparation, field testing, interpretation and reporting

2.        Non-conducting Pipe Types include: VCP, RCP, ACP, Plastic, CIPP

3.        Portability: Ability to test in limited access areas such as backyard easements.

4.        Output Data

Quantitative: Numeric output readily incorporated into GIS, databases and summary tables for condition assessment and grading

Qualitative: Descriptive output difficult to incorporate into GIS, databases and summary tables for condition assessment and grading.

Highly dependant on judgment and experience of test operator/interpreter

5.        Potential leak defects: Pipe structural, service lateral connection and joint defects that will allow infiltration or exfiltration. Liquid flow through the defect may or may not be occurring at the time of the test.

6.        QA Testing: The effectiveness of the test to assure that the rehabilitation method has repaired the pipe defects.


Metrotech Corporation, 488 Tasman Drive, Sunnyvale, CA 94089. Ph: (408) 734-1400