home contact us analysis summary terms of use |
FELL
Electro-Scan One-step Sewer Leak Detection & Location |
| Electro-Scan Current Trace ACP diameter: 8 inch + show joint locations Lateral from restaurant enters main at 30 |
Current
Trace Shows: Joints have large defects from 30 to 90 Significant structural defects from 33 to 53 - possible corrosion |

| Electro-Scan
Current Trace CIPP diameter: 8 inch 200 to 360 VCP diameter: 8 inch 360 to 400 |
Current
Trace Shows: Joints OK, Manhole at 215, Defective service connections at 295 and 317 Significant structural defects 393 to 400 |