Electro-Scan Current Trace
ACP diameter: 8 inch  + show joint locations
Lateral from restaurant enters main at 30
Current Trace Shows:
Joints have large defects from 30 to 90
Significant structural defects from 33 to 53 - possible corrosion
curent trace ACP pipe
Electro-Scan Current Trace
CIPP diameter: 8 inch 200 to 360
VCP diameter: 8 inch 360 to 400
Current Trace Shows:
Joints OK, Manhole at 215, Defective service connections at 295 and 317
Significant structural defects 393 to 400